Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Braz. J. Vet. Res. Anim. Sci. (Online) ; 57(3): e166095, 2020. ilus, tab, graf
Article in English | VETINDEX, LILACS | ID: biblio-1122191

ABSTRACT

Copaifera langsdorffii is a Brazilian native plant that is used for wound healing or as an anti-inflammatory agent. Non-healing wounds are an important health problem, particularly in horses, because they can cause the animal invalidity or even lead to death. In addition, horses respond to skin wounds with chronic inflammatory response and intense wound granulation, thereby delaying the healing process. By this way, our aim was to evaluate the healing potential of Copaifera langsdorffii hydroalcoholic extract (HE) and oil-resin creams (OR) in horse skin wounds. Four wounds were performed bilaterally in the lumbar region of six horses with a 2 cm punch and treated daily with the respective treatments: saline solution, vehicle, 10% HE creams or 10% OR cream. Daily planimetry analyses were performed to measure the wound area and clinical parameters. In four different experimental periods (3, 7, 14 and 21 d), wound biopsies were removed and used for microscopic analyses. SS wounds presented a significant small area at day 3 and 7, OR wounds presented significant small area in comparison with HE at 14 d, and no significant difference was observed between treatments at 21 d. A better microscopic and clinical healing activity of HE and OR was identified in comparison with the controls. The OR group showed better healing quality, specifically after 7 d of treatment. Therefore, Copaifera langsdorffii formulations demonstrated their wound healing potential in horse skin lesions, exhibiting an improvement of the macro- and microscopic parameters.(AU)


Copaifera langsdorffii é uma planta nativa brasileira usada para cicatrização de feridas e como agente anti-inflamatório. As feridas que não cicatrizam são um importante problema de saúde em equinos, devido à possibilidade de afastamento da carreira atlética ou até mesmo levar à morte. Além disso, os cavalos respondem às feridas com resposta inflamatória crônica e intensa granulação, atrasando o processo cicatricial. Dessa forma, o presente trabalho avaliou o potencial do extrato hidroalcoólico (EH) e cremes de óleo resina (OR) de Copaifera langsdorffii em feridas cutâneas de equinos. Quatro feridas de 2 cm foram realizadas bilateralmente na região lombar de seis equinos e tratadas diariamente com: solução salina, veículo, creme EH 10% ou creme OR 10%. Diariamente foi efetuada a análise macroscópica das feridas e planimetria para mensurar a área da ferida. Em quatro períodos experimentais diferentes (3, 7, 14 e 21 dias), as biópsias foram realizadas e utilizadas para análises microscópicas. As análises microscópica e clínica indicaram melhor resposta cicatricial nas feridas tratadas com HE e OR em comparação com os controles. O grupo OR apresentou melhor qualidade de cicatrização, especificamente após sete dias de tratamento. Portanto, as formulações de Copaifera langsdorffiiutilizadas apresentaram potencial de cicatrização de feridas em lesões de pele de cavalo, exibindo uma melhora nos parâmetros macro e microscópicos.(AU)


Subject(s)
Animals , Wound Healing , Wounds and Injuries/veterinary , Horses , Fabaceae , Resins, Plant/therapeutic use , Phytotherapy/veterinary
2.
Rev. bras. oftalmol ; 71(4): 227-232, jul.-ago. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-650654

ABSTRACT

OBJETIVO: Alterações oculares, em especial a perda de volume nas cavidades evisceradas, promovem uma série de modificações ao paciente tanto funcional do órgão quanto psicológica e estética. Para tanto a procura de um material de baixo custo e com biocompatibilidade tem sido uma constante na literatura. Portanto, esse trabalho teve como objetivo testar experimentalmente implante de polietileno granulado de ultra-alto peso molecular, material de baixo custo, em órbitas de coelhos submetidos à evisceração cirúrgica em vários tempos experimentais, onde foram avaliados aspectos macroscópicos e microscópicose de toxicidade sistêmica do material. MÉTODOS: Para esse estudo foram utilizados coelhos Oryctolaguscuniculus submetidos à evisceração do globo ocular direito e posteriormente implantados com esfera de polietileno granulado de ultra-alto peso molecular e analisados por 15, 30, 90 e 180 dias pós-implante, com parâmetros macro, microscópios e bioquímicos. Os animais controles foram submetidos ao mesmo procedimento sem, entretanto a colocação do implante. RESULTADOS: Os resultados desse trabalho mostram que o material utilizado no implante de cavidade não apresenta alteração significativa nos parâmetros de peso e bioquímicos quando comparados ao grupo controle. O material implantado apresentou uma grande interação com o tecido do hospedeiro. CONCLUSÃO: Os resultados indicam que implante de polietileno granulado de alto peso molecular desenvolvido por uma indústria nacional tem alto potencial para se realizar testes em humanos.


OBJECTIVE: Ocular changes in special due to volume loss in eviscerated cavities promote several psychological aesthetic and functional alterations to patients. For this reason, searches aiming at finding a material of low cost and biocompatibility have been constantly carried out. Test experimentally the implants constituted of ultra-high molecular weight granular polyethylene oflow cost, in orbits of rabbits subjected to surgical evisceration in several experimental times, evaluating the macro and microscope aspects besides the systemic toxicity of the material. METHODS: In this study we eviscerated the right ocular globe of rabbits of the species Oryctolaguscuniculus, implanted posteriorly a sphere of granular polyethylene of ultrahigh molecular weight and analysed the effects through macro, micro and biochemical parameters during 15, 30, 90 and 180 days after implantation.The control group were submitted the same procedure without the implants. RESULTS: This paper shows that the material used in the cavity does not present significant alteration in the weight and in the biochemistry of the animal; a good assimilation (integration) of the material implanted by the tissue formed was observed inside the implant. CONCLUSION: The results indicate that ultra-high molecular weight granular polyethylene implant developed by a national industry presents excellent integration in the model used supporting further use in tests with humans.


Subject(s)
Animals , Rabbits , Anophthalmos/surgery , Eye, Artificial , Orbital Implants , Orbit Evisceration , Polyethylenes/therapeutic use , Clinical Trial , Prospective Studies
3.
Acta cir. bras ; 24(1): 7-12, Jan.-Feb. 2009. ilus, tab
Article in English | LILACS | ID: lil-503098

ABSTRACT

PURPOSE: To evaluate the effect of low intensity laser on the pseudocapsula contraction that occurs around silicone implants. METHODS: 60 male rats divided in two experimental groups received a silicone implant in the subcutaneous of the dorsal region. Group I: animals received implants in the subcutaneous dorsal region and did not receive any treatment; Group II: animals received seven irradiation sessions with low intensity laser after they had received subcutaneous implants. Thirty, 60 and 180 days after the surgery, tonometric evaluation of the implants was conducted. After that, the animals were sacrificed, study material was removed and prepared for histological examination. The thickness of the pseudocapsule and the inflammatory reaction were morphometrically quantified. Data obtained were statistically analyzed using the Variance method, and Tukey's Test(P<0.0 5). RESULTS: Group II animals had significant lower pressure. The histological study did not show a significant difference between the groups, but only a higher number of swollen vessels in Group II. The thickness of pseudocapsule around Group II's implants lower than in Group I. CONCLUSION: The low intensity laser modify tissue's reparation process around the implants suggesting it may be useful to model contractures that are formed around silicone implants.


OBJETIVO: Avaliar o efeito do laser de baixa intensidade sobre a contração da pseudocápsula que ocorre ao redor de implantes de silicone. MÉTODOS: 60 ratos machos divididos em dois grupos receberam implante de silicone. Grupo I: implante no subcutâneo da região dorsal, sem tratamento após a cirurgia; Grupo II: animais receberam sete sessões de irradiação com laser de baixa intensidade após o implante. Trinta, 60 e 180 dias após a cirurgia, foi feita a tonometria dos implantes, Em seguida, os animais foram sacrificados, removendo-se o material de estudo que foi preparado para exame histológico, avaliando-se morfometricamente a espessura da pseudocápsula e a reação inflamatória. A análise estatistica pela técnica da Análise de Variância e Teste de Tukey (P<0.0 5). RESULTADOS: Pressões significativamente menores foram encontradas nos animais do grupo Grupo II. O estudo histológico não mostrou diferença significativa entre os grupos, destacando-se apenas maior quantidade de vasos intumescidos no Grupo II. A espessura da pseudocápsula foi menor no Grupo II. CONCLUSÃO: O laser de baixa intensidade altera o processo de reparação tecidual ao redor dos implantes, sugerindo que o mesmo possa ser útil para a modelação das contraturas que se estabelecem ao redor dos implantes de silicone.


Subject(s)
Animals , Male , Rats , Breast Implants , Implants, Experimental , Low-Level Light Therapy , Silicones , Analysis of Variance , Contracture/pathology , Contracture/prevention & control , Contracture/radiotherapy , Disease Models, Animal , Models, Animal , Random Allocation , Rats, Wistar
4.
An. bras. dermatol ; 84(1): 35-40, jan.-fev. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-511462

ABSTRACT

FUNDAMENTOS: A quitosana é polímero derivado da quitina, com vários tipos de aplicação na área médica. OBJETIVO: Avaliar a biocompatibilidade de membranas de quitosana no subcutâneo de ratos. MÉTODOS: Foram utilizados 20 ratos "Wistar" machos, nos quais foram implantadas membranas de quitosana, na região mediana dorsal. Os animais foram sacrificados: sete, 15, 30 e 60 dias após a cirurgia, tendo sido avaliados clinicamente durante o período experimental e com fotodocumentação no momento do sacrifício. Após o sacrifício, as membranas e tecidos adjacentes foram removidos e preparados para exame histológico e morfométrico. RESULTADOS: Nenhum animal apresentou efeitos adversos que pudessem ser atribuídos à implantação das membranas. O exame histológico mostrou que as inclusões são lisas e homogêneas e não são colonizadas por células do hospedeiro, sendo circundadas por pseudocápsula composta por fibroblastos e células inflamatórias. A morfometria da pseudocápsula revelou espessura semelhante durante todo o período experimental (P>0,05). CONCLUSÃO: A quitosana pode ser opção para uso como implante não integrado. Novos estudos devem ser realizados para comprovar a biocompatibilidade a longo prazo.


Background: Chitosan is a polymer derivative from chitin applied in many medical specialties. Objective: To evaluate the biocompatibility of chitosan membranes used as inclusion material into subcutaneous of rats. Methods: Twenty male Wistar rats received chitosan membranes into the subcutaneous area of the dorsal medial region. The animals were randomly divided in four groups with 5 animals each, sacrificed on 7th (G1), 15th (G2), 30th (G3) and 60th (G4) postoperative day (PO). All animals were clinically evaluated daily and by photo-documentation at the sacrifice moment. The animals and the material were assessed for evidence of host response by histological and morphometric evaluation of the implants and the surrounding soft tissues. The material was fixed in 10% formalin and then the sections were stained with hematoxylin and eosin. Results: None of animals presented side effects attributable to the implants. The histological evaluation showed smooth and homogeneous inclusions with no host cells inside and were encircled by a pseudocapsule of fibroblasts and inflammatory cells. The morphometric evaluation showed no statistical difference between different groups (P>0.05). Conclusion: Chitosan membrane might be suggested as an option of non-integrated implant. Otherstudies have to be carried out to evaluate longstanding biocompatibility.


Subject(s)
Animals , Male , Rats , Chitosan , Materials Testing , Prostheses and Implants , Subcutaneous Tissue , Rats, Wistar , Subcutaneous Tissue/anatomy & histology , Subcutaneous Tissue/surgery
5.
Rev. bras. oftalmol ; 66(4): 227-230, jul.-ago. 2007. ilus, tab
Article in Portuguese | LILACS | ID: lil-481136

ABSTRACT

OBJETIVO: Avaliar o uso do programa AutoCAD 2004 para estudos quantitativos em microscopia eletrônica. MÉTODOS: A demonstração da utilização do AutoCAD 2004 foi feita em um modelo experimental de diabetes induzido em ratos, divididos em Grupo Controle (GC-10 animais) e Grupo Diabético (GD - 10 animais), avaliados 1 mês depois da indução do diabetes. Os olhos foram removidos após o sacrifício dos animais e preparados para exame em microscópio eletrônico, tendo sido feitas fotografias dos vasos retinianos. Foi utilizado o programa AutoCAD2004 para avaliar a espessura da membrana basal dos vasos. Os resultados foram avaliados estatisticamente. RESULTADOS: Usando o método proposto foi possível realizar medidas quantitativas na membrana basal de vasos retinianos de ratos diabéticos. CONCLUSÃO: O AutoCAD 2004 se mostrou efetivo, seguro e de fácil utilização para a quantificação de fenômenos biológicos, sendo possível sugerir este meio para a realização de avaliações quantitativas em experimentos biológicos.


OBJECTIVE: To determine if the AutoCAD 2004 program is available to be used in quantitative research on electron microscopy. METHODS: A demonstrative of the AutoCAD2004 was done in an experimental model of diabetes induced in rats. The animals were divided by lot in control group animals (GC-10 animals) and diabetic group (GD - 10 animals), evaluated 1 month after the diabetes induction. The eyes were removed after sacrifice and prepared to electron microscopy. The retina was photographed and the AutoCAD2004 program was used to measure the basal membrane of retina vessels. The results were submitted to statistical analysis. RESULTS: The AutoCAD2004 was effective to obtain quantitative measures from the basal membrane of retina vessels and there were no difference between the studied groups. CONCLUSION: The AutoCAD2004 was effective, safe and easy to apply to quantify biological parameters, which allowed suggest it to quantitative research.


Subject(s)
Animals , Rats , Alloxan/administration & dosage , Diabetes Mellitus, Experimental/chemically induced , Microscopy, Electron/methods , Retinal Vessels , Software , Weights and Measures , Rats, Inbred Strains
6.
Arq. bras. oftalmol ; 69(6): 827-829, nov.-dez. 2006. tab
Article in Portuguese | LILACS | ID: lil-440419

ABSTRACT

OBJETIVO: Quantificar a gordura presente no músculo levantador da pálpebra de portadores de ptose congênita, correlacionando este achado com fatores clínico-epidemiológicos desta afecção. MÉTODOS: Vinte e duas amostras de músculo levantador da pálpebra superior, provenientes de portadores de ptose congênita, foram avaliadas morfometricamente, com o intuito de quantificar a gordura presente nos espécimes e correlacionar este achado com características como idade, sexo, grau de ptose e função do músculo levantador. RESULTADOS: Não houve correlação entre a quantidade de gordura encontrada no músculo levantador de portadores de ptose congênita e os dados clínicos dos pacientes estudados. CONCLUSÃO: A quantidade de gordura presente no músculo levantador da pálpebra superior, nas condições do presente estudo, não está associada com idade, sexo, grau de ptose ou função do músculo levantador. Novos estudos serão necessários para avaliar a real alteração que ocorre no músculo levantador da pálpebra de indivíduos com ptose palpebral.


PURPOSE: To quantify the fat in the levator muscle of patients with congenital ptosis, as related to clinical and epidemiological aspects of this disease. METHODS: Twenty-two levator muscle samples of the superior eyelid from patients with congenital ptosis were morphometrically evaluated with aim of establishing a relationship between the fat quantity and age, sex, ptosis degree and levator muscle function. RESULTS: According to our results the fat in the levator muscle of patients with congenital ptosis is not related to gender or epidemiologic aspects. CONCLUSION: Fat amount in the levator muscle from congenital ptosis is not related to age, sex, ptosis degree or levator muscle function. Other studies will be necessary to show the real alterations in the levator muscle related to eyelid ptosis.


Subject(s)
Humans , Male , Female , Infant , Child, Preschool , Child , Adolescent , Adult , Adipose Tissue/pathology , Blepharoptosis/congenital , Blepharoptosis/pathology , Eyelids/pathology , Oculomotor Muscles/pathology , Age Factors , Blepharoptosis/surgery , Eyelids/surgery , Oculomotor Muscles/physiology , Oculomotor Muscles/surgery , Sex Factors , Statistics, Nonparametric
7.
Arq. bras. oftalmol ; 66(3): 321-324, maio-jun. 2003. ilus, tab
Article in Portuguese | LILACS | ID: lil-345643

ABSTRACT

OBJETIVO: Analisar os efeitos da ingestão crônica de álcool sobre o nervo óptico em um modelo murino adulto. MÉTODOS: Doze ratos machos da raça Wistar, de 30 dias de idade, foram divididos por sorteio em 2 grupos experimentais: "tratado" (TG), com 8 animais, alimentados com ração-padrão para roedores de laboratório e uma mistura de água de torneira e etanol ad libitum; "controle" (CG), com 4 animais, alimentados com a mesma ração e água de torneira pura ad libitum. Após 40 semanas todos os ratos foram sacrificados, sendo os nervos ópticos de ambos os olhos preparados para microscopia óptica e eletrônica. A área de secção transversal de cada nervo a aumento de 500x, assim como número de fibras axonais dentro de 5 campos aleatoriamente selecionados a aumento de 2000x foram medidos com auxílio de digitalizador de imagens acoplado ao microscópio óptico. Foram realizadas fotomicrografias de 10 campos aleatoriamente selecionados de cada nervo (5 centrais e 5 periféricos) a aumento de 4200x em microscópio eletrônico de transmissão. RESULTADOS: A análise morfométrica não mostrou diferenças estatisticamente significativas entre os 2 grupos estudados. Em contraste com o CG, o exame ultra-estrutural dos nervos ópticos do TG mostrou um intenso desarranjo das bainhas de mielina, que se tornaram espessadas, com separação de suas lamelas, apresentando, por vezes, degenerações interlamelares elétron-densas, além da presença de muitas organelas degeneradas. CONCLUSÃO: Os achados desse estudo mostram alterações ultra-estruturais no nervo óptico de ratos adultos após ingestão crônica de álcool, sem modificações morfométricas significativas.


Subject(s)
Animals , Male , Rats , Ethanol , Optic Nerve/cytology , Optic Nerve/ultrastructure , Ethanol , Microscopy, Electron/methods , Microscopy , Rats, Wistar
SELECTION OF CITATIONS
SEARCH DETAIL